Industrial Legionella Field Testing Kit Legionella Test Results in 25 Minutes Downloads Testing Kits Contact Us Quote Industrial Kit Data Sheet Single Swab Kit Data Sheet Single Syringe Kit Data Sheet Swab Test Kit Data Sheet Why Choose HydroSense Brochure Legionella Single Swab Test Kit Single Syringe Legionella Test Kit Legionella Field Testing Swab Kit Industrial Legionella Field Testing Kit For support regarding any of our Legionella control services, please contact a Legionella Control Systems Representative. Hours: Monday thru Friday 8-5 EST Tel: +1 888-416-8626 Email: [email protected] Contact us for a Quote Tel: +1 888-416-8626 Email: [email protected] The industrial Legionella field testing kit is a breakthrough technology from Hydrosense for the rapid detection of Legionella bacteria in water samples taken from pipework fittings. Fast results High sensitivity In-line sampling Ideal for plumbing system and industrial samples The test kit contains all the items required to perform 5 tests and includes a fitting for connection to water systems. This kit is designed for connection to plumbing systems, such as hot and cold water pipework and industrial water systems, such as cooling towers. The filtration step needs no pumping: just connect the sample point to the water system and use the system pressure to drive the filtration. Single-use filtration modules. Pre-filled syringe containing recovery buffer, no need to measure or dilute solutions. The test is simple to use and fast, with no interpretation required. Results are easy to read and obtained within 30 to 35 minutes. An immediate result minimizes delays and downtime. Use can reduce the risk of outbreaks and litigation. Regular use will The industrial Legionella field testing kit uses an immunochromatographic assay, to detect the presence of cell surface antigens from Legionella bacteria in a sample. The presence of antigen causes the “Test Line” to turn red in colour. A “Control Line” is included which should always turn red if the test has been performed correctly. Bacteria detected Legionella pneumophila serogroup Detection method Lateral flow immunochromatographic assay Lower limit of detection As low as 100 CFU/L (0.1 CFU/mL) Specificity Tested against a wide range of waterborne bacteria, including: Acinetobacter calcoaceticus, Aeromonas hydrophila subsp. hydrophila, Bacillus subtilis, Burkholderia cepacia, Citrobacter freudii, Citrobacter koseri, Escherichia coli, Enterobacter cloacae, Klebsiella oxytoca, Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, Ralstonia pickettii, Raoultella terrigena, Streptococcus pyrogenes, Yersinia ruckeri. No cross reactions observed at concentrations ≤ 109 CFU/L. Staphylococcus aureus has been observed to cross react with the test at concentrations > 108 CFU/L , which is higher than found in most water samples. Legionella pneumophila serogroups 4 & 7 cross react with the test at concentrations >109 CFU/sample. The test does not react with any other L. pneumophila serogroups or L. species tested. Test volume 100 μL Suggested sample volume 250 μL Sample parameters Sample should filter in less than 10 minutes. Biocides The product has been tested with a range of common biocides and biodispersants used in Legionella control, at their normal maximum operating concentration. Active ingredients tested include: glutaraldehyde, didecyl-dimethyl-ammonium chloride, isolthazoles, dibromonitrilopropionamide, ionic and non-ionic surfactants. The test gives a false positive if used with systems treated with polymeric biguanide or THPS. It should not be used to test such systems. Operator time 5-10 minutes Test time 25 minutes Sample point fitting Supplied with both ½” and ¾” female threaded fittings. Additional sample points are available (part no. 100171). Shelf life At least 6 months from date supplied, when stored at room temperature (<30°C) in original packaging. All test strips are hermetically foil-wrapped with a printed expiry date. Contact Us We can help you with your Legionella risk assessment, Legionella testing, Legionella remediation, and everything else you need to control Legionella. Contact the Legionella experts at [email protected] or 888-416-8626 right now. By Chris Nancrede. Last Updated: July 8, 2026 Request Proposal Contact Us